Description
Specifications
| Model | Power-Sonic PS-12750U (PS General Purpose series) |
| Voltage | 12V (6 cells) |
| Capacity | 75Ah @ 10 hr (the number in the name) · 80Ah @ 20 hr · 68.5Ah @ 5 hr · 47.3Ah @ 1 hr |
| Stored energy | 960 Wh |
| Chemistry | Sealed lead acid, AGM, valve regulated, maintenance free |
| Length | 260 mm (10.24 in) |
| Width | 168 mm (6.61 in) |
| Height (case / over terminal) | 208 mm (8.19 in) / 214 mm (8.43 in) |
| Approx. weight | 22.7 kg (50.04 lb) |
| Terminal | U (universal: L-terminal with bolt-through hole and threaded insert; confirm hardware on arrival) |
| Max continuous discharge | 750 A |
| Internal resistance | 7.2 mΩ |
| Case | ABS (UL94 HB, V-0 optional) |
| Operating temp | Charge -20 to 50°C (-4 to 122°F) · Discharge -15 to 60°C (5 to 140°F) |
| Dimensional tolerance | ±2 mm (±0.08 in) |

Cross-reference
These are common 12V 75Ah Group 24 sealed AGM numbers in the same size class as the PS-12750U. The footprint is close; the terminals often are not. Match voltage, size and terminal style to your old battery, or send us a photo of the label.
| Part / model | Terminal | Match notes |
|---|---|---|
| PS-12750U | U (nut-and-bolt L-terminal with M6 insert) | This battery. Official size 260 x 168 x 208 mm, 214 mm total height. |
| PS-12750 M6 | M6 insert | Same Power-Sonic battery, different terminal. |
| PS-12750 FR M6 | M6 insert, flame-retardant case | Same Power-Sonic battery, FR case, different terminal. |
| UB12750 (UPG 45821) | Z or I6 posts (post with bolt hole) | 12V 75Ah at the 20-hour rate. Case 260.1 x 167.9 x 210.1 mm (about 2 mm taller than the PS case). Total height 231.9 mm vs 214 mm on the PS. Same footprint; check the posts. |
| NP75-12 (EnerSys / Genesis / Yuasa) | Standard U on the 2003 sheet; optional NB and other styles. Many replacement NP75-12 units are sold with M6 inserts. | 12V 77.5Ah at the 20-hour rate. The May 2003 EnerSys sheet lists 10.67 x 6.66 in (271 x 169 mm), about 58 lb — longer than this PS. Measure your old battery before you order. |
| DCM0075U (Interstate) | UT (stud) | 12V 75Ah, Group 24. Official size 260.10 x 167.89 x 211.07 mm (case about 3 mm taller). Check the terminal. |
| SLA1175 (Interstate) | Flag on Interstate’s current product page (some sheets say nut-and-bolt) | 12V 75Ah, Group 24. Interstate’s product page: 260.10 x 167.89 x 232.41 mm, flag terminals. A Nash spec sheet for the same number lists 259 x 168 x 208 mm, 214 mm total height, nut-and-bolt — the two sources disagree, so check the physical battery. |
Same size, check your terminal style. The PS-12750U uses a U terminal (nut-and-bolt L-terminal with an M6 insert). UB12750 is commonly sold with Z or I6 posts, NP75-12 with a U or an M6 insert, DCM0075U with a UT stud, and SLA1175 with flag terminals on Interstate’s current listing. If the posts on your old battery do not match, this will not bolt up even when the case fits.
Need dual terminals instead? See our Rocket 12V 75Ah Dual Terminal battery (RKT12750DT), which also replaces UB12750 and NP75-12. If you have U or L-tab terminals, this Power-Sonic PS-12750U is the one to use.
FAQ
Will it fit my equipment?
Match three things to your old battery: voltage (12V), size (about 10.24 x 6.61 x 8.19 in) and terminal type (U). If all three match, it fits. If you’re not sure, send us a photo of the old label.
Why does the capacity change with the hour rating?
It’s the same battery rated at different discharge speeds. Power-Sonic rates it at 75Ah @ 10 hr (the number in the name) , 80Ah @ 20 hr , 68.5Ah @ 5 hr , 47.3Ah @ 1 hr. Drain it faster and you get fewer amp-hours out. When comparing batteries, compare the same hour rate.
How should I charge it?
Use a charger made for sealed lead acid / AGM. For standby (float) use, hold it at 13.5 to 13.8V. For cycling, charge at 14.1 to 14.4V and keep the starting current under 24 A, then drop to float. Power-Sonic recommends the PSC-126000ACX. Don’t use an old-style unregulated charger.
How long will it last?
In standby use (alarm panels, UPS) it’s designed for about 5 years of float service at room temperature. Heat shortens that. In cycling use it depends on depth of discharge: shallow discharges give many more cycles than running it flat. Recharge right after use, and if it’s stored, give it a freshening charge at least every 6 months.
My equipment uses more than one. Should I replace them all?
Yes. In UPS units and other systems that wire batteries in series or parallel, replace the whole set at once with the same model. A new battery mixed with worn ones gets overworked and fails early.
For installers, IT and fleets
We supply alarm and security installers, UPS and IT teams, medical and mobility shops, and fleet and facilities buyers. Buying by the case? Call 1-800-276-8002 or email us for volume.